    Features:


    • Enhanced EMI / EMC performance
    • 25Gbps data transfer rate per channel, up to 100Gbps
    • Compliant with the IEEE 802.3bj standard and Infiniband EDR specifications
    • Meets QSFP + MSA and SFF-8661 / SFF-8665 standards
    • Support serial ID function through EEPROM
    • 30AWG to 26AWG cable available
    • RoHS and halogen-free options

    Description

     

    Applications :

    • Switch / router / HBA / SAN, NIC card
    • 40G \ 100G Ethernet
    • Storage, switch, data center, network center
    • Infiniband, QDR / EDR

     

    Electrical Performance

    • Signal Integrity

    ITEM

    REQUIREMENT

    TEST CONDITION

    Differential Impedance

    Cable Impedance

    105+5/-10Ω

    Rise time of 25ps

    (20 % - 80 %).

     

    Paddle Card Impedance

    100±10Ω

    Cable Termination Impedance

    100±15Ω

    [Differential (Input/Output)Return loss SDD11/SDD22]

    Return_loss(f)

     

    Where

    f    is the frequency in GHz

    Return loss(f)  is the return loss at frequency f

    10MHz≤f ≤19GHz

    [Differential to common-mode (Input/Output)Return loss SCD11/SCD22]

    Return_loss(f)

     

    Where

    f              is the frequency in GHz

    Return_loss(f)  is the Differential to common-mode return loss at frequency f

    10MHz≤f ≤19GHz

    [Common-mode to Common-mode

    (Input/Output)Return loss SCC11/SCC22]

    Return_loss(f)2dB      0.2f19

    Where

    f              is the frequency in GHz

    Return_loss(f) is the common-mode to common-mode return loss at frequency f

    10MHz≤f ≤19GHz

    [Differential Insertion Loss (SDD21  Max.)]

     

    (Differential InsertionLoss Max. For TPa to TPb Excluding Test fixture )

    10MHz≤f ≤19GHz

               F            AWG

    1.25GHz

    2.5GHz

    5.0GHz

    7.0GHz

    10Ghz

    12.89Ghz

    30(1m)Max.

    4.5dB

    5.4dB

    6.3dB

    7.5dB

    8.5dB

    10.5dB

    30/28(3m)Max.

    7.5dB

    9.5dB

    12.2dB

    14.8dB

    18.0dB

    21.5dB

    26(3m)Max.

    5.7dB

    7.2dB

    9.9 dB

    11.9dB

    14.1dB

    16.5dB

     

    26/25(5m)Max.

     

    7.8dB

     

    10.0dB

     

    13.5dB

     

    16.0dB

     

    19.0dB

     

    22.0dB

     

    [Insertion Loss Deviation]

    -0.176*f - 0.7  ILD  0.176* f + 0.7

    50MHz≤f ≤19GHz

    Differential to common-mode Conversion Loss-Differential Insertion Loss(SCD21-SDD21)

     

    Conversion _loss(f) – IL(f)

     

    Where

    f                   is  the frequency in GHz

    Conversion_loss(f )  is  the cable assembly differential to common-mode conversion loss

    IL(f)                is  the cable assembly insertion loss

    10MHz≤f ≤19GHz

    [MDNEXT(multiple disturber

    near-end crosstalk)]

    ≥35dB @12.89GHz

    10MHz≤f ≤19GHz

    [Intra Skew]

    15ps/m,

    10MHz≤f ≤19GHz

     

     

     

     

    6.2 Other Electrical Performance

    ITEM

    REQUIREMENT

    TEST CONDITON

    [Low Level Contact Resistance]

    70milliohms Max. From initial.

    EIA-364-23:Apply a maximum voltage of 20mV

    And a current of 100 mA.

    Insulation Resistance

    10Mohm(Min.)

    EIA364-21:AC 300V 1minute

     [Dielectric Withstanding Voltage]

    NO disruptive discharge.

    EIA-364-20:Apply a voltage of 300 VDC for 1minute between adjacent terminals

    And between adjacent terminals and ground.

     

    • Environment Performance

    ITEM

    REQUIREMENT

    TEST CONDITON

    [Operating Temp. Range]

    -20°C to +75°C

    Cable operating temperature range.

    [Storage Temp. Range

    (in packed condition)]

    -40°C to +80°C

    Cable storage temperature range

    in packed condition.

    [Thermal Cycling Non-Powered]

    No evidence of physical damage

    EIA-364-32D, Method A, -25 to 90C, 100 cycles, 15 min. dwells

    [Salt Spraying]

    48 hours salt spraying after shell

    corrosive area less than 5.

    EIA-364-26

    Mixed Flowing Gas

    Pass electrical tests per 3.1 after

    stressing. (For connector only)

    EIA-364-35 Class II,14 days.

    Temp. Life

    No evidence of physical damage

    EIA-364-17C w/ RH, Damp heat 90 at 85% RH for 500 hours then return to ambient

    Cable Cold Bend

    4H,No evidence of physical damage

    Condition: -20±2, mandrel diameter is 6 times the cable diameter.

     

     

     

    • Mechanical and Physical Characteristics

    ITEM

    REQUIREMENT

    TEST CONDITON

    Vibration

    Pass electrical tests

    per 3.1 after stressing.

    Clamp & vibrate per EIA-364-28E,

    TC-VII, test condition letter – D, 15 minutes in X, Y & Z axis.

    Twist

    No evidence of physical damage

    Twist cable 180° (±90° from nominal position) for 100 cycles at 30 cycles per minute with a 0.5kg load applied to the cable jacket.

    Clamp position: 300mm

    Cable Flex

    No evidence of physical damage

    Flex cable 180° for 20 cycles (±90° from nominal position) at 12 cycles per minute with a 1.0kg load applied to the cable jacket. Flex in the boot area 90º in each direction from vertical. Per EIA-364-41C

    Cable Plug Retention in Cage

    90N Min.

    No evidence of physical damage

    Force to be applied axially with no damage to cage. Per SFF 8661 Rev 2.1

    Pull on cable jacket approximately 1 ft behind cable plug. No functional damage to cable plug below 90N.

    Per SFF-8432 Rev 5.0

    Cable Retention in Plug

    90N Min.

    No evidence of physical damage

    Cable plug is fixtured with the bulk cable hanging vertically. A 90N axial load is applied (gradually) to the cable jacket and held for 1 minute. Per EIA-364-38B

    Mechanical Shock

    Pass electrical tests

    Per 3.1 after stressing.

    Clamp and shock per EIA-364-27B, TC-G,3 times in 6 directions, 100g, 6ms.

    Cable Plug Insertion

    40N Max.(QSFP28)

    Per SFF8661 Rev 2.1

    Cable plug Extraction

    30N Max. (QSFP28)

    Place axial load on de-latch to de-latch plug.Per SFF8661 Rev 2.1

     

    Durability

    50 cycles,No evidence of physical damage

    EIA-364-09, perform plug &unplug cycles:Plug and receptacle mate rate: 250times/hour. 50times for QSFP28/SFP28 module (CONNECTOR TO PCB)

     